Reference Center
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
The process side of the exchanger shows all areas including the baffle
with excessive material loss.
A ruptured exchanger tube was discovered after a hydro test.
It appears the tube failed due to thinning of the tube wall.
Shell-side inspections with remote video tools such as videoscopes are used to verify the
condition of the tubes and shell and the extent of shell-side fouling in an exchanger.
Shell-side corrosion and fouling can be identified and evaluated using remote video camera
systems such as small-diameter, articulating videoscopes.
Various Issues
Future Video
Click to Download PDF
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Exchanger Tube Bacterial Corrosion
This bacterial corrosion was caused by an ineffective cooling water treatment program.A
videoscope was used to determine the extent of the corrosion throughout the facility.
Non-contact measurement software was used to quantify the pitting.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Exchanger Tube Fouling and Pitting
Video scopes are excellent tools for determining the internal conditions of exchanger tubes.
Techniques such as eddy current only supply numbers for supposed wall loss. Remote video
can differentiate conditions such as fouling, scale, corrosion, and pitting before using
software to accurately measure features.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Tube Walls Thinned and Blown Out
Vibration may have be associated with the tube failure
where the tube has completely broken off.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Exchanger Tube Broke off at Baffle
Many of our clients have used videoscopes to locate and determine the cause of
failures in tubes.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Tube Walls Thinned and Failed
A hole is clearly visible with pitting indications.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Tube Walls Thinned and Pitted
Aluminum had deposited and built up in this tube over time. The presence and thickness of
this build-up was verified using a remote camera system and non-contact measurement
software.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Blown Exchanger Tube
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Aluminum Build-up in Tube
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Cooling Water Side Conditions
Chronicle Archive Present to Past
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Corrosion on Tube OD
Click on magazine for
Present to Past Issues
This video shows corrosion at the start of a tube near the tube sheet.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Corrosion Near Tubesheet
This video shows corrosion at the rolled area of the tube.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Corrosion at Rolled Area of Tube
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Leak at Row 4 Tube 13
This video shows tube corrosion and wall loss.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Corrosion and Wall Loss
.
A videoscope was used to inspect this tube for fouling.  Debris was also noted in this tube.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Condenser Tube Fouled & Foreign Object
This foreign object was noted during a tube side inspection of an exchanger
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Fin Fan Tube Scale & Foreign Object
This image shows fouling on the inside diameter of an exchanger tube pass.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Exhcnager Tube Fouled Pass
Corrosion is clearly visible in this video of the inside diameter of a heat exchanger tube.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Internal Corrosion of Heat Exchanger Tube
This image shows cluster pitting on the inside diameter of tubes in a sales exchanger. Using
non-contact measurement software, Maverick is able to provide size measurements of
features such as pitting.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Cluster Pitting Due to Sour Glycol
in Sales Exchanger
This video shows random tubes of the Exchanger with excessive scale fouling.
.
Magnetec Inspection, Inc.
Magnetec Inspection, Inc.
Initial Pre-Cleaning Inspection of Exchanger Tube
Bundle for Preparation Prior to Chemical Cleaning
Customer Updates, Manuals, Extras
Click on document for
Customer Updates,
Manuals & Extras